Old 11-17-2008, 09:33 AM
Gashmore Gashmore is offline
Junior Member
 
Join Date: Aug 2008
Posts: 20
Default Dynex Dux redux

I have finally started some quantitative testing on a sample of 9mm Dynex Dux that John at Colligo sent me. I have not completed the creep test but the dynamic stretch figures are in. I am getting a page together on my web site with all the gory details but I thought I would report the preliminary results here.

The purpose of my examination is to get some numbers to compare to 1x19 wire. I tried to follow the Cordage Institute's procedures but as the sample had only 28" clear of undisturbed rope I used an electronic positioning sensor called an LVDT capable of detecting .00005" movement. By adjusting for the specific weight of the rope I had estimated from Strong Ropes figure of .00055 in/in/1000lb for 11mm that 9mm should have an elongation of .00084, about equivalent to 5/16" 1x19. The tested figure (average of 20 pulls after 50 cycles to 20% of MBL was slightly better at .00078 in/in/10000lb. I have to attribute this to the possibility that the fiber is slightly more in line with the load in the smaller diameters.

One major difference I found was the hysteresis or rate of recovery after the load is removed. 1x19 will recover 90% or more of the elongation immediately and the rest over just a few seconds. Relaxed from 5,000lb to 2,000lb Dux only recovers about 60% immediately and another 30% over the next half hour to 45 minutes. It took almost 12 hours to recover all the elongation. What I think this means is that you shouldn't try to tune a rig immediately after it has been loaded heavily. If you dial in the tension before the shroud has fully recovered it will be to tight a few hours later. Also I think it is possible that the leeward shrouds might seem slightly slack immediately after a tack. I will have to examine this more closely.

The other interesting fact is the almost complete lack of torsional deformation. 1x19 will try to rotate as the lay straightens but braid remains in line. I don't think I would do away with cotter pins in the turn buckle though. :-)

Creep test begins next week and will take a couple of months.
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is On


All times are GMT -7. The time now is 09:57 PM.


Powered by vBulletin® Version 3.6.7
Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.