EDUCATION | CATALOG | RIGGING | CONSULTATION | HOME | CONTACT US |
#5
|
|||
|
|||
![]() Brion,
Thanks for the additional comments. Since I have bought the turnbuckles with toggles on both ends, I will go ahead and use them even though it maybe redundant. I am now working on how to compute the constructional and working elasticity for my new wire. I was looking at your examples in The Rigger's Apprentice. I do not have a scientific calculator, and pretty poor at math,, and I was wondering if there is a table for different lengths and diameters of 1X19 SS wire for this computation. I have tried some interpolation and must admit it is pretty random, but using the example in the book as a starting point with 50' 5/16 1X19 SS tuned to a working load of 25%, showing a working stretch of 1.5 inches and about 5/32 of an inch for construcitonal stretch. For my uppers that are 7/32 1x19 SS around 32 feet in length, I would think that the constructional stretch would be nominal, possibly 1/16 of an inch and if given around 3/4 of an inch for working elasticity I should be in the ball park? Again this is just my throwing out some interpolation than that of actually crunching numbers. I just don't want to guess to much stretch and end up with to short of a wire. With lowers of 1/4 inch 1X19 SS of only around 15 feet, would it be possible to omit any stretch calculations all together? Thanks for all the great advise. Fair Winds. |
Thread Tools | |
Display Modes | |
|
|